An arc fault detection device (AFDD) is a switchboard device that cuts power to a circuit when it detects electrical arcing, the sparking that happens across a loose connection or damaged cable. Arcing can start a fire without drawing enough current to trip a circuit breaker or leaking enough to trip a safety switch. An AFDD watches for that specific fault.
AFDDs are still unfamiliar to most Australian homeowners, and they are not required in a typical house. They do cover a fault the rest of your switchboard can miss, and in some homes that makes them worth adding.
What is an arc fault?
An arc fault is electricity jumping across a gap where it should be flowing through solid metal. The gap might be a screw terminal that has worked loose in a power point, a cable nicked by a nail or screw during a renovation, a flex crushed under furniture, or insulation chewed by rats in the ceiling. Current keeps crossing that gap as a tiny, intermittent spark.
Each spark is small, but it is extremely hot, and it carbonises the plastic and timber around it. Over days or months that charring can become conductive, the arcing gets worse, and eventually something catches. Arcing is one of the causes behind a burning smell from a power point, and it often gives no other warning.
Electricians talk about two kinds. A series arc happens along a single conductor, such as a loose terminal or a cable broken partway through. A parallel arc happens between two conductors, for example where damaged insulation lets the active and neutral spark across to each other.
Why don't circuit breakers and safety switches catch it?
Because an arc fault usually looks normal to both of them. A circuit breaker trips when a circuit carries more current than its rating, from an overload or a short circuit. A series arc sits in the path of the normal load and actually restricts the current a little, so the breaker sees nothing wrong.
A safety switch (RCD) trips when current leaks to earth, which is how it stops an electric shock. An arc between the active and neutral, or along one conductor, does not leak anything to earth, so the safety switch stays on too. An arc that tracks to earth may trip it, but the safety switch is not designed to look for arcing.
| Device | What it trips on | What it can miss |
|---|---|---|
| Circuit breaker | Overload and short circuit | Leakage to earth, and arcing that stays under the rating |
| Safety switch (RCD) | Current leaking to earth | Overloads, and arcing that does not leak to earth |
| AFDD | The electrical signature of series and parallel arcing | Leakage and overload on its own, so it is usually combined with an RCBO |
Each device covers a different fault, which is why the newer products stack them together rather than replacing one with another. Our guide to RCBO vs RCD covers the first two in more detail.
How does an AFDD work?
An AFDD has electronics that read the shape of the current waveform many times a second and recognise the pattern arcing produces. A dangerous arc creates rapid, irregular spikes of high-frequency noise on the circuit. When the device sees that pattern persist, it opens the circuit, typically within a fraction of a second.
The hard part is telling a dangerous arc from a harmless one. Flicking a light switch, pulling out a plug and running a drill with brushes all make brief arcs. AFDDs built to the international standard IEC 62606 are tested against these everyday sources so they ignore them. Many models also show which fault caused a trip, arcing, overload or leakage, which saves time when an electrician comes to find the problem.
In Australia, most AFDDs are sold as a combined unit: an AFDD and an RCBO in one device. That gives a single circuit arc, overload, short circuit and shock protection, and it usually takes the same slot, or one slot more, than the RCBO it replaces.
Wondering what your switchboard protects against?
DM Electrical can check your board, tell you which circuits have breaker, safety switch and arc fault protection, and what is missing. Based in Brookvale, Level 1 and Level 2 ASP accredited, available 24/7 across the Northern Beaches and wider Sydney.
Are AFDDs required in Australia?
Not in a typical house. An amendment to the AS/NZS 3000 Wiring Rules published in 2021 introduced a recommendation for AFDDs in situations where an electrical fire carries a higher risk, for example buildings with sleeping accommodation, buildings with combustible construction, and places storing irreplaceable items. It is advice rather than a rule, so an existing board without AFDDs is not non-compliant.
North America went further: arc fault breakers there, called AFCIs, have been required on new bedroom circuits for over twenty years.
Which homes get the most out of one?
The value is highest where wiring is old, hidden or likely to be damaged, and where a fire would be hard to escape. These are the situations where we would raise AFDDs with a customer.
- Bedroom circuits. A fire that starts at night in a wall cavity is the scenario AFDDs were designed for.
- Older timber homes. Decades-old cable, brittle insulation and a timber frame are a poor combination. Plenty of Northern Beaches homes fit.
- Recently renovated houses. Every nail, screw and plasterboard fixing near a cable is a chance of a nicked conductor that will not show up until it starts arcing.
- Rentals, granny flats and holiday homes. Places where the owner is not there to notice a smell or a warm power point.
- Circuits with heavy plug-in loads. Heaters, kettles and power boards on extension leads stress plugs and sockets, the most common spot for a loose, arcing connection.
Can you add AFDDs to an existing switchboard?
Usually, yes, if the board is in good condition and has space. The combined AFDD and RCBO unit simply replaces the existing breaker or RCBO on the chosen circuit, so many homes can add them circuit by circuit. A board with ceramic fuses or no spare room has to be upgraded first, and at that point it often makes sense to plan arc protection into the new board from the start. Our switchboard upgrade page explains what a replacement involves.
Cost depends heavily on the board and how many circuits you protect. As a general guide, a combined AFDD and RCBO typically costs several times the price of a standard RCBO, which works out at roughly $250 to $500 per circuit supplied and fitted, depending on brand, board space and how much work is done at once. That is a general range, not a quote.
An AFDD will not fix wiring that is already failing. If an older house has wiring that is already deteriorating, the right first step is an inspection, which a residential electrician can carry out, so damaged cabling is replaced rather than simply monitored.
Frequently asked questions
Are AFDDs mandatory in Australia?
Not for a standard house. Since a 2021 amendment, the AS/NZS 3000 Wiring Rules recommend arc fault detection devices in some higher-risk situations, such as buildings with sleeping accommodation or combustible construction, but it is a recommendation rather than a requirement.
Can an AFDD be added to my existing switchboard?
Usually, if the board has space and is in good condition. Most AFDDs sold in Australia combine arc detection with an RCBO, so they replace the existing breaker for that circuit. A board with ceramic fuses or no spare room needs to be upgraded first.
Will an AFDD trip on my appliances?
Rarely. AFDDs are designed to ignore the normal arcing from light switches, plugs and motors with brushes. Older or faulty equipment can occasionally trigger one, and when it does, the device is often pointing at something worth having checked.
Does an AFDD replace a safety switch?
No. A safety switch protects people from electric shock by detecting current leaking to earth, while an AFDD protects the building from fires started by arcing. The combined units sold in Australia do both jobs, plus overload protection, in one device.
The bottom line
An AFDD detects arcing, a common cause of electrical fires that breakers and safety switches are not designed to pick up. It is not required in a typical Australian house, and it is no substitute for sound wiring and working smoke alarms, but on bedroom circuits, older timber homes and properties that sit empty, it is a sensible addition. Get in touch and we will tell you whether your board can take them and which circuits are worth doing first.